What is it about?

In isolated type LLC resonant converters, transformer leakage inductance can be merged with the resonant inductor to extend the ZVS capability of the switches apart from isolation and voltage scaling. However, the transformer presents a resonant imbalance in the secondary side leading to secondary current unbalance, an increase in RMS value of the secondary current and increase thermal stress. This paper proposed a half-bridge non-isolated LLC resonant converter with a balanced rectifying current and stress in the rectifier diodes.

Featured Image

Why is it important?

The converter can achieve the most advantages of isolated LLC converters, such as ZVS and low MOSFET turn-off loss. By the non-isolation method, secondary current and, transformer loss is significantly reduced. In addition, rectifier diodes operate with zero current switching and balanced rectifying current and stress over the entire operating range.

Read the Original

This page is a summary of: Non-isolated LLC resonant DC-DC converter with balanced rectifying current and stress, Indonesian Journal of Electrical Engineering and Computer Science, May 2020, Institute of Advanced Engineering and Science,
DOI: 10.11591/ijeecs.v18.i2.pp698-706.
You can read the full text:

Read

Contributors

The following have contributed to this page