What is it about?
Percutaneous RF ablation is one of alternative treatment for non-surgical liver tumors. Ablative changes in hepatic tissue can be successfully estimated using the finite element method. The authors created a 3D model of a multi-tine applicator immersed in liver tissue, and then determined the optimal values of voltage applied to such an RF electrode, which do not exceed the therapeutic temperature range valid during thermal ablation procedure. Importantly, the simulations were carried out for the RF electric probes with 2 to 5 evenly spaced arms. Additionally, the thermal damage of hepatic tissue for multi-armed applicators working at predefined limit values of voltages was established based on the Arrhenius model.
Featured Image
Why is it important?
Key words: percutaneous RF ablation ; multi-tine electrode ; tumor heating techniques ; Arrhenius thermal damaged model; hepatocellular carcinoma ; finite element method
Perspectives
https://journals.pan.pl/dlibra/publication/129339/edition/112883/content
Dr. Piotr Gas
AGH University of Science and Technology
Read the Original
This page is a summary of: Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating, Archives of Electrical Engineering, June 2023, Polish Academy of Sciences Chancellery,
DOI: 10.24425/aee.2019.129339.
You can read the full text:
Contributors
The following have contributed to this page