What is it about?
There is very limited literature describing the different flow of hydraulic pumps working parallel and simultaneously in one hydraulic power pack unit. Several investigators have presented analysed hydraulic central power pack with multipump structure as a single-pump with capacity equal simple multiplication of the some smaller standard pump. Such simplified models of the power packs move to the analysis of the single big hydraulic pump, not as group independent smaller pumps. It lead to mistake.
Featured Image
Photo by Andrew Neel on Unsplash
Why is it important?
Our finding show that in the practice different adjustments of regulators move to different flows of individual pumps during simultaneously work in one power pack unit. The non-proportional flow problem creating in such power pack structure and having the influence on total output flow and power
Perspectives
Read the Original
This page is a summary of: Problem of Non Proportional Flow of Hydraulic Pumps Working with Constant Pressure Regulators in Big Power Multipump Power Pack Unit in Open System, Tehnicki vjesnik - Technical Gazette, April 2019, Mechanical Engineering Faculty in Slavonski Brod,
DOI: 10.17559/tv-20161119215558.