What is it about?
We are analysing the influence of different design factors on the maximum reachable strains for an equibiaxial dielectric elastomer actuator (DEA). The design factors analyzed in the study are the dielectric elastomer thickness, the electrode radius and the pre-stretch. For the analysis, a full factorial design without and with interactions and a fractional factorial design are choosen.
Featured Image
Photo by Nadine Shaabana on Unsplash
Why is it important?
The study enables to quantify the influence of the different design factors and their interactions and presents a selection of statistically relevant factors and interactions. The fractional factorial design allows the reduction of the number of measurements without loosing main aspect of the study.
Perspectives
This study provides a valuable insight into the influencing factors and interactions for equibiaxial dielectric elastomer actuators.
Simon Holzer
Ecole Polytechnique Federale de Lausanne
Read the Original
This page is a summary of: Study of Potential Factors and their Interaction in Dielectric Elastomer based Cell Stretcher, November 2023, Institute of Electrical & Electronics Engineers (IEEE),
DOI: 10.1109/icems59686.2023.10345117.