What is it about?
This paper details the advanced natural fire simulations that were carried out for the composite steel-reinforced concrete structure of the JTI Building in Geneva, Switzerland. The results of these analyses led to a significant reduction in the fireproofing of the steel floor framing. Several scenarios of different thermal behaviours of the peripheral cladding were studied.
Featured Image
Why is it important?
Application of SAFIR analyses on complex geometry structures with large spans in the 2 directions
Perspectives
The method is suitable for common administrative buildings with large spans and large fire compartments
Lorenzo Lelli
Politecnico di Milano
Read the Original
This page is a summary of: Advanced analyses of the membrane action of composite slabs under natural fire scenarios, Journal of Structural Fire Engineering, March 2018, Emerald,