What is it about?
The paper presents the impact of Pulse Width Modulation (PWM) control frequency for specific Permanent Magnet Synchronous Motors (PMSMs) on the efficiency of the entire driving unit. Examinations were carried out for a PMSM unit with a power of 1 kW, rated speed of 1000 rpm, and rated torque of 6 Nm.
Featured Image
Why is it important?
This work shows that there is some maximal efficiency of the entire system depending on the rotation speed, load torque and switching frequency of the power transistors. For specific motor working in certain condition we can find the minimum power loss.
Perspectives
Writing this article was a great pleasure as it has co-authors with whom I have had long standing collaborations.
Tomasz Rudnicki
Silesian University of Technology
Read the Original
This page is a summary of: Impact of PWM control frequency on efficiency of drive with 1kW permanent magnet synchronous motor, COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, November 2017, Emerald,