What is it about?

The paper deals with flow of wet water steam in diffuser of turbine engine 1090 MW on saturated water steam. Experimental measurements were done while the turbine was in operation for a wide range of outputs. Defining the outlet velocity from the last stage and with knowledge of static pressures on the diffuser outlet, it is possible to define the contribution of the diffuser to the whole low pressure part efficiency.

Featured Image

Why is it important?

There is a lack of experimental research done in steam turbine in power plants. This paper should partly correct this problem and show some basic results deals with steam turbine diffuser behaviour.

Perspectives

This paper provides very perspective results because of measurement is done in real steam turbine.

Ph.D. Michal Hoznedl
Doosan Group

Read the Original

This page is a summary of: Experimental investigation on flow in diffuser of 1090 MW steam turbine, January 2016, American Institute of Physics,
DOI: 10.1063/1.4953707.
You can read the full text:

Read

Contributors

The following have contributed to this page