Owing to different parameter tolerances of the primary windings, grid current could be unbalanced, which usually could not be solved through traditional control methods. To handle this problem, a current balancing method is adopted in this paper to improve former current control loop. Meanwhile, based on the principle of instantaneous power balance, a dual loop control strategy with an outer voltage loop and an inner current loop is designed. Besides, load current feedforward control is introduced to enhance the dynamic response. Moreover, phase-shift control is employed as the modulation method, in which duty ratios change along with sinusoidal signals.

Featured Image

Read the Original

This page is a summary of: Practical Consideration and Implementation of Three-Phase AC-DC Converter with Power Factor Correction Function Based on Integrated Transformer, IET Power Electronics, May 2020, the Institution of Engineering and Technology (the IET),
DOI: 10.1049/iet-pel.2019.1415.