What is it about?

This paper presents a new orthogonal signal generation (OSG) technique for the control system of a single-phase grid-connected voltage-source converter (VSC). The existing methods mostly suffer from delay, rely on the system parameters or require multiple inputs. Among them the second-order generalized integrator (SOGI) excludes the drawbacks of the other methods and shows better steady-state and dynamic response. The proposed OSG method in this paper includes the advantages of the SOGI technique while demonstrating superior dynamic response and higher disturbance rejection capability. It is structurally simple without adding complexity to the control system. The proposed method is implemented in a DQ-frame current controller and its feasibility and reliability are verified through mathematical analysis, simulation and experimental results.

Featured Image

Read the Original

This page is a summary of: An Enhanced Orthogonal Signal Generator for a Single-phase Grid-Connected Converter , IET Power Electronics, October 2018, the Institution of Engineering and Technology (the IET),
DOI: 10.1049/iet-pel.2018.5253.