What is it about?
Ammonia, high temperature and high humidity have adverse effects on animals during long distance livestock export from Australia to the Middle East, but none of these is effectively measured currently. On the basis of data maps obtained on two voyages of live sheep export, this study determined sampling strategies for ammonia, temperature and humidity measurement on the vessel. The difference between predicted high and low ammonia sites on the shipment could be detected with approximately 5 measurement sites of each. Margins of error were determined, which suggested that dry bulb temperature could be measured with 6e8 measurement sites, but even 20 measurement sites were not sufficient to measure relative humidity. For the vessel recorded, considerably more ammonia measurement sites are required on closed decks than on open decks, with less variation for temperature measurement. The number of pens measured contributed more to the variance of ammonia and temperature measurement than the number of sampling locations within each pen on open decks. This study highlights the importance of a suitable sampling strategy to measure ammonia, temperature and relative humidity on board ship during live export.
Featured Image
Read the Original
This page is a summary of: Development of an effective sampling strategy for ammonia, temperature and relative humidity measurement during sheep transport by ship, Biosystems Engineering, March 2017, Elsevier,
DOI: 10.1016/j.biosystemseng.2016.11.010.
You can read the full text:
Contributors
The following have contributed to this page