All Stories

  1. Quantitative assessment of tooth wear using intraoral scanners: A comparative analysis of two monitoring tools
  2. Quantitative and Color‐Coded Assessment of Crown Preparation Using a 3D‐Printed Channel and Hole Guide: A Pilot Comparison With Conventional Guides
  3. Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing: a geometric library matching approach
  4. Influence of postprinting cleaning methods on the cleaning efficiency and surface and mechanical properties of three-dimensionally printed resins
  5. Influence of crown shade, translucency, and scan powder application on the trueness of intraoral scanners
  6. Volumetric Analysis of Peri-implant Tissue Change Over Time: Validating an Innovative 3D Method
  7. Influence of limited mouth opening in children on intraoral scanning accuracy: An in vitro study
  8. Reliability of digital repeated-scan superimposition and single-scan techniques for wear volume loss assessment on flat surfaces
  9. Strength and Surface Characteristics of 3D-Printed Resin Crowns for the Primary Molars
  10. AUTONOMOUS ROBOTIC SURGERY SEEMS PROMISING AS AN ACCURATE TECHNOLOGY FOR SINGLE-TOOTH IMPLANT PLACEMENT IN THE ESTHETIC ZONE
  11. Three-Dimensional Peri-Implant Tissue Changes in Immediately vs. Early Placed Tapered Implants Restored with Two Different Ceramic Materials—1 Year Results
  12. A comprehensive study on the mechanical effects of implant-supported prostheses under multi-directional loading and different occlusal contact points
  13. 3D analysis of occlusal registration through geometry embedded library matching between quadrant and full-arch digital impression
  14. Guided Autotransplantation of Impacted Canines Using a CAD/CAM Surgical Template
  15. Automated vector analysis to design implant-supported prostheses: A dental technique
  16. Bisphenol A release from commercially available 3-dimensionally printed resins and human cell apoptosis to bisphenol A: an in-vitro study
  17. Occlusal adjustment of 3-unit tooth-supported fixed dental prostheses fabricated with complete-digital and -analog workflows: A crossover clinical trial
  18. Strategy to obtain an accurate occlusal registration using intraoral scanners
  19. Stress distribution in pediatric zirconia crowns depending on different tooth preparation and cement type: a finite element analysis
  20. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: A finite element analysis study
  21. Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants
  22. Mechanical Properties of Additively Manufactured and Milled Interim 3‐Unit Fixed Dental Prostheses
  23. Digital Wear Analysis of Different CAD/CAM–Fabricated Monolithic Ceramic Implant- Supported Single Crowns Using Two Optical Scanners
  24. Comparison of digital and conventional assessment methods for a single tooth preparation and educational satisfaction
  25. Retention force and stress distribution analysis of the cementless double crown–type implant-supported prosthesis
  26. Three‐dimensional evaluation of tooth preparation forms in paediatric zirconia crowns: An in vitro study
  27. Influence of adjacent teeth on the accuracy of intraoral scanning systems for class II inlay preparation
  28. Customized surgical guide with a bite block and retraction arm for a deeply impacted odontoma; a technical note
  29. Evaluation of the effect of contamination of the scan-mirror of an intra-oral scanner on the accuracy of the scan data: A pilot study
  30. A Survey on dental personnel’s perceptions of digital dentistry and dental digital equipment
  31. Accuracy of Customized Abutment Data Superimposition According to the Extent of the Scanning Area
  32. Fundamental understandings of mesh process and various formats of digital data in digital dentistry
  33. Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis
  34. Full mouth rehabilitation with vertical dimension increase in patient with severely worn out dentition: A case report
  35. Implant-assisted removable partial denture using digital guide surgery in partially edentulous mandible: A case report
  36. In vitro analysis of intraoral digital impression of inlay preparation according to tooth location and cavity type
  37. Implant placement in the removable mandibular advancement device for completely edentulous patients: a finite element study
  38. Three-Dimensional Evaluation of Peri-implant Soft Tissue When Tapered Implants Are Placed: Pilot Study with Implants Placed Immediately or Early Following Tooth Extraction
  39. Feasibility of 3-Dimensional Visual Guides for Preparing Pediatric Zirconia Crowns: An In Vitro Study
  40. Accuracy of Vertical Dimension Augmentation Using Different Digital Methods Compared to a Clinical Situation—A Pilot Study
  41. In silico evaluation of the peripheral and inner seals in complete denture master impressions using a custom-developed 3D software
  42. Validation of a three‐dimensional printed model for training of surgical extraction of supernumerary teeth
  43. CAD-CAM milled dentures: The Geneva protocols for digital dentures
  44. Virtual diagnostics and guided tooth preparation for the minimally invasive rehabilitation of a patient with extensive tooth wear: A validation of a digital workflow
  45. Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report
  46. A conversion to implant assisted removable partial denture in failed fixed implant prosthesis of mandible: A case report
  47. Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report
  48. Implant-assisted removable partial denture using milled bar and Locator in partially edentulous maxilla: A case report
  49. Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads
  50. Fabrication of dentures for a patient with unstable mandibular movements: A case report
  51. Interdisciplinary Approach to Treat Unusual Development of Dens Evaginatus: A Case Report
  52. Changes in Density of Peri-implant Bone due to Bone Remodeling according to Implant Structure and Initial Conditions
  53. Evaluating the Wear of Resin Teeth by Different Opposing Restorative Materials
  54. Designing a mandibular advancement device with topology optimization for a partially edentulous patient
  55. Feasibility of a 3D Surgical Guide Technique for Impacted Supernumerary Tooth Extraction: A Pilot Study with 3D Printed Simulation Models
  56. A CAD-CAM device for preparing guide planes for removable partial dentures: A dental technique
  57. Combining Conventional Impressions and Intraoral Scans: A Technique for the Treatment of Complete Denture Patients with Flabby Tissue
  58. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible
  59. Effect of additional firing process after sintering of monolithic zirconia crown on marginal and internal fitness
  60. Effects of cementless fixation of implant prosthesis: A finite element study
  61. Three-Dimensional Digitalized Surface and Volumetric Analysis of Posterior Prefabricated Zirconia Crowns for Children
  62. Biomechanical effect of mandibular advancement device with different protrusion positions for treatment of obstructive sleep apnoea on tooth and facial bone: A finite element study
  63. A Method for Minimizing Rotational Errors of Implant Prostheses
  64. Precise Reproduction of Soft Tissue Structure around the Pontic Area Using Computer-Aided Design and Manufacturing
  65. A simplified method for evaluating the 3-dimensional cement space of dental prostheses by using a digital scanner
  66. Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length
  67. Comparative Analysis of Screw Loosening With Prefabricated Abutments and Customized CAD/CAM Abutments
  68. Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis