All Stories
- Metal debris release is commonly seen from explanted total ankle replacements
Article

- A common allele of HLA is associated with asymptomatic SARS-CoV-2 infection
Article

- Periarticular metal hypersensitivity complications of hip bearings containing cobalt–chromium
Article

- The influence of HLA genotype on the development of metal hypersensitivity following joint replacement
Article

- Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial inserts
Article
- The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty
Article

- The Influence Of Hla Genotype On The Severity Of Covid‐19 Infection
Article

- THE INFLUENCE OF HLA GENOTYPE ON SUSCEPTIBILITY TO, AND SEVERITY OF, COVID-19 INFECTION
Article
- Cemented Exeter total hip arthroplasty with a 32 mm head on highly crosslinked polyethylene
Article
- Is the synovial fluid cobalt-to-chromium ratio related to the serum partitioning of metal debris following metal-on-metal hip arthroplasty?
Article
- Letter to the Editor: Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions
Article

- Material loss at the femoral head taper
Article
- Engineering standards for trauma and orthopaedic implants worldwide: a systematic review protocol
Article

- Aseptic lymphocyte-dominated vasculitis-associated lesions are related to changes in metal ion handling in the joint capsules of metal-on-metal hip arthroplasties
Article
- Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation
Article

- A comparison study of stem taper material loss at similar and mixed metal head-neck taper junctions
Article
- A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis
Article

- Azzopardi phenomenon reported in metal-on-metal arthroplasties is in fact iron encrustation of blood vessels
Article

- Investigation of Taper Failure in a Contemporary Metal-on-Metal Hip Arthroplasty System Through Examination of Unused and Explanted Prostheses
Article

- Letter to the Editor on “Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip”
Article

- Response to Letter to the Editor on “Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip”
Article

- Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint
Article
- Mechanistic Study of the Wear of Ceramic Heads by Metallic Stems in Modular Implants
Article

- Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy
Article

- The clinical implications of metal debris release from the taper junctions and bearing surfaces of metal-on-metal hip arthroplasty: joint fluid and blood metal ion concentrations
Article
- Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a national retrieval centre
Article

- The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur
Article
- Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system
Article

- Feasibility of asymmetric flow field-flow fractionation coupled to ICP-MS for the characterization of wear metal particles and metalloproteins in biofluids from hip replacement patients
Article

- Adverse sequelae following revision of a total hip replacement for a fractured ceramic component: case report
Article

- Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine
Article

- Practical considerations for volumetric wear analysis of explanted hip arthroplasties
Article
- Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: A nanoindentation study?
Article

- Are Metal Ion Levels a Trigger for Surgical Intervention?
Article

- Blood metal ion testing is an effectivescreening tool to identify poorly performing metal-on-metal bearingsurfaces
Article
- European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing
Article

- Déclaration de consensus européen multidisciplinaire au sujet de l’utilisation et de la surveillance des surfaces articulaires métal/métal dans les prothèses totales standard ou de resurfaçage
Article

- The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study
Article

- Consensus statement “Current evidence on the management of metal-on-metal bearings” - April 16, 2012
Article
- Correction
Article

- Taper junction failure in large-diametermetal-on-metal bearings
Article
- Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing: From a single, non-designer surgeon
Article
- Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties
Article

- Ongoing problems with metal-on-metal hip implants
Article

- Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
Article

- Accelerating failure rate of the ASR total hip replacement
Article
- Quantification of self-polishing in vivo from explanted metal-on-metal total hip replacements
Article

- A study of the wear of explanted metal-on-metal resurfacing hip prostheses
Article

- High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS
Article
- Reducing Metal Ion Release Following Hip Resurfacing Arthroplasty
Article

- Adverse reaction to metal debris following hip resurfacing: THE INFLUENCE OF COMPONENT TYPE, ORIENTATION AND VOLUMETRIC WEAR
Article
- P-8 Metal-on-Metal Resurfacing Hip Prostheses: Hero or Villain?
Article

- S-41 The Wear of Explanted Resurfacing Hip Prostheses
Article

- Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System
Article

- Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A CONSEQUENCE OF EXCESS WEAR
Article
- Articular Surface Replacement of the hip: a prospective single-surgeon series
Article
- Blood metal ion concentrations after hip resurfacing arthroplasty: A COMPARATIVE STUDY OF ARTICULAR SURFACE REPLACEMENT AND BIRMINGHAM HIP RESURFACING ARTHROPLASTIES
Article
- Tribological analysis of failed resurfacing hip prostheses and comparison with clinical data
Article

- The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
Article
- The Influence of Age and Sex on Early Clinical Results After Hip Resurfacing
Article
