All Stories

  1. Lung-DDPM: Semantic Layout-Guided Diffusion Models for Thoracic CT Image Synthesis
  2. Fast personalized CT dose calculations with GPUMCD
  3. Predicting Episodes of Hypovigilance in Intensive Care Units Using Routine Physiological Parameters and Artificial Intelligence: Derivation Study
  4. PyOrthanc: A Python Interface for Orthanc DICOM Servers
  5. Bias Mitigation in Primary Health Care Artificial Intelligence Models: Scoping Review
  6. Implementing Multifactorial Risk Assessment with Polygenic Risk Scores for Personalized Breast Cancer Screening in the Population Setting: Challenges and Opportunities
  7. Identifying Episodes of Hypovigilance in Intensive Care Units Using Routine Physiological Parameters and Artificial Intelligence: a Derivation Study (Preprint)
  8. Bias Mitigation in Primary Health Care Artificial Intelligence Models: Scoping Review (Preprint)
  9. Exploring the application of dual‐energyCTto discriminate sediment facies in a varved sequence
  10. The Cross-Scale Association between Pathomics and Radiomics Features in Immunotherapy-Treated NSCLC Patients: A Preliminary Study
  11. A Monte Carlo dose recalculation pipeline for durable datasets: an I-125 LDR prostate brachytherapy use case
  12. Risk of Bias Mitigation for Vulnerable and Diverse Groups in Community-Based Primary Health Care Artificial Intelligence Models: Protocol for a Rapid Review
  13. Risk of Bias Mitigation for Vulnerable and Diverse Groups in Community-Based Primary Health Care Artificial Intelligence Models: Protocol for a Rapid Review (Preprint)
  14. La gouvernance des données dans le domaine de la santé : Pour une fiducie de données au Québec ?
  15. X-Ray Computed Tomography to Measure Bed Density in Sand Transport
  16. Aspects juridiques de l'IA en santé - Fiche 3
  17. Beam-hardening corrections through a polychromatic projection model integrated to an iterative reconstruction algorithm
  18. Définitions et usages de l’IA en santé - Fiche 1
  19. Enjeux éthiques de l’IA en santé - Fiche 4
  20. Promesses de l’IA en santé - Fiche 2
  21. Identification of Common Minerals Using Stoichiometric Calibration Method for Dual‐Energy CT
  22. Personalized Risk Assessment for Prevention and Early Detection of Breast Cancer: Integration and Implementation (PERSPECTIVE I&I)
  23. Veille sur les outils numériques en santé dans le contexte de COVID-19
  24. Recension des solutions technologiques développées dans le monde afin de limiter la propagation de la COVID-19 et typologie des applications de traçage
  25. Dose to the bladder neck is not correlated with urinary toxicity in patients with prostate cancer treated with HDR brachytherapy boost
  26. Evaluating the impact of real-time multicriteria optimizers integrated with interactive plan navigation tools for HDR brachytherapy
  27. Potential of iterative reconstruction for maxillofacial cone beam CT imaging: technical note
  28. Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT
  29. Validation of irtGPUMCD, a GPU-based Monte Carlo internal dosimetry framework for radionuclide therapy
  30. DNA repair gene polymorphisms, tumor control, and treatment toxicity in prostate cancer patients treated with permanent implant prostate brachytherapy
  31. Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction
  32. A Phase 2 Randomized Pilot Study Comparing High-Dose-Rate Brachytherapy and Low-Dose-Rate Brachytherapy as Monotherapy in Localized Prostate Cancer
  33. Iterative reconstruction for image enhancement and dose reduction in diagnostic cone beam CT imaging
  34. A GPU-based multi-criteria optimization algorithm for HDR brachytherapy
  35. pGPUMCD: an efficient GPU-based Monte Carlo code for accurate proton dose calculations
  36. A multi-criteria optimization approach for HDR prostate brachytherapy: I. Pareto surface approximation
  37. A multi-criteria optimization approach for HDR prostate brachytherapy: II. Benchmark against clinical plans
  38. A fast 4D cone beam CT reconstruction method based on the OSC-TV algorithm
  39. Does Seed Migration Increase the Risk of Second Malignancies in Prostate Cancer Patients Treated With Iodine-125 Loose Seeds Brachytherapy?
  40. System matrix computation vs storage on GPU: A comparative study in cone beam CT
  41. Efficiency improvement in proton dose calculations with an equivalent restricted stopping power formalism
  42. COMP report: CQPR technical quality control guidelines for CT simulators
  43. Multicenter Evaluation of Biochemical Relapse–Free Survival Outcomes for Intraoperatively Planned Prostate Brachytherapy Using an Automated Delivery System
  44. Validation of the French-Canadian version of the Expanded Prostate Cancer Index Composite (EPIC) in a French-Canadian population
  45. A review of GPU-based medical image reconstruction
  46. Conception and characterization of a virtual coplanar grid for a 11×11 pixelated CZT detector
  47. High-dose-rate brachytherapy boost for prostate cancer treatment: Different combinations of hypofractionated regimens and clinical outcomes
  48. A CZT-based blood counter for quantitative molecular imaging
  49. Does prostate volume has an impact on biochemical failure in patients with localized prostate cancer treated with HDR boost?
  50. Image-guided high-dose-rate brachytherapy boost to the dominant intraprostatic lesion using multiparametric magnetic resonance imaging including spectroscopy: Results of a prospective study
  51. CT dose reduction: approaches, strategies and results from a province-wide program in Quebec
  52. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT
  53. A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation
  54. Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy
  55. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications
  56. Special section: Selected papers from the Fifth International Workshop on Monte Carlo Techniques in Medical Physics
  57. Does Large Prostate Volume Has an Impact on Biochemical Failure in Patients With Localized Prostate Cancer Treated With HDR Boost?
  58. Fast GPU-based computation of spatial multigrid multiframe LMEM for PET
  59. GPU-accelerated regularized iterative reconstruction for few-view cone beam CT
  60. Evaluation of the OSC-TV Reconstruction Algorithm for Optical Cone-Beam Computed Tomography
  61. A CdZnTe-based automated Blood Counter for Quantitative Molecular Imaging
  62. Sci-Thur PM: Imaging - 05: Calibration of a SPECT/CT camera for quantitative SPECT with 99m Tc
  63. Sci—Thur AM: YIS - 03: irtGPUMCD: a new GPU-calculated dosimetry code for 177Lu-octreotate radionuclide therapy of neuroendocrine tumors
  64. HDR Brachytherapy Boost for Prostate: Dosimetry and Toxicity Comparison Study Based on Prostate Volumes
  65. Acute and Late Toxicity in Patients Treated with Selective High-Dose-Rate Image-Guided Boost to Dominant Intraprostatic Lesion
  66. Fast GPU-based computation of the sensitivity matrix for a PET list-mode OSEM algorithm
  67. Real-time processing in dynamic ultrasound elastography: A GPU-based implementation using CUDA
  68. Sci-Sat AM: Brachy - 07: Plastic scintillation detector validation for kV dosimetry
  69. TH-F-211-04: A Fast Finite Size Pencil Beam Algorithm for Dose Calculation Using GPUs
  70. Special section: Selected papers from the Fourth International Workshop on Recent Advances in Monte Carlo Techniques for Radiation Therapy
  71. The importance of an exponential prostate-specific antigen decline after external beam radiotherapy for intermediate risk prostate cancer
  72. Cervical Lymph Node Metastases From Unknown Primary Cancer: A Single-Institution Experience With Intensity-Modulated Radiotherapy
  73. The Role of Computed Tomography in the Management of the Neck After Chemoradiotherapy in Patients With Head-and-Neck Cancer
  74. Simultaneous Integrated Boost Using Intensity-Modulated Radiotherapy Compared With Conventional Radiotherapy in Patients Treated With Concurrent Carboplatin and 5-Fluorouracil for Locally Advanced Oropharyngeal Carcinoma
  75. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range
  76. Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD
  77. 18F-FDG-PET imaging in radiotherapy tumor volume delineation in treatment of head and neck cancer
  78. Fast dose calculation in magnetic fields with GPUMCD
  79. Validation of GPUMCD for low-energy brachytherapy seed dosimetry
  80. SU-E-I-172: Fast Computation of High Resolution LOR-Based 3D OSEM PET Algorithm Using the GPU Device
  81. SU-E-T-683: Improvement of LDR Brachytherapy TG-43 Dose Calculations with a GPU-Accelerated Raytracing Algorithm
  82. TU-E-BRB-04: Fast Monte Carlo Calculations in Magnetic Fields with GPUMCD for the MRI-Linac
  83. Enteral Feeding During Chemoradiotherapy for Advanced Head-and-Neck Cancer: A Single-Institution Experience Using a Reactive Approach
  84. GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform
  85. Concurrent Chemoradiation With Carboplatin–5-Fluorouracil Versus Cisplatin in Locally Advanced Oropharyngeal Cancers: Is More Always Better?
  86. A convolution-superposition dose calculation engine for GPUs
  87. SU-FF-T-417: Effect of Transverse Magnetic Fields On MV Photon Dose Distributions in Heterogeneous Media
  88. SU-FF-T-622: Fast GPU-Based Raytracing Dose Calculations for Brachytherapy in Heterogeneous Media
  89. TH-D-BRD-02: Convolution-Superposition Dose Calculations with GPUs
  90. Fast convolution-superposition dose calculation on graphics hardware
  91. Fast Dose Calculations in Radiation Therapy with GPUs
  92. SU-GG-I-144: Validation of a Monte Carlo Model of the PET Component of the Gemini GXL PET/CT
  93. TU-EE-A4-06: Fast DRR and CBCT Reconstruction On GPU
  94. Stream processors: a new platform for Monte Carlo calculations
  95. Monte Carlo simulations of compact gamma cameras based on avalanche photodiodes
  96. FFT and cone-beam CT reconstruction on graphics hardware
  97. Joint registration of multiple images using entropic graphs
  98. Modeling and Correction of Spatial Distortion in Position-Sensitive Avalanche Photodiodes
  99. Evaluation of a MR-compatible CZT detector
  100. Investigation of a continuous crystal PSAPD-based gamma camera
  101. Resolution enhancement in digital x-ray imaging
  102. A multipinhole small animal SPECT system with submillimeter spatial resolution
  103. Reducing the Distortion in Resistive Layer Positioning Devices: A Simulation Study
  104. Comparison of Position-Sensitive versus Discrete Avalanche Photodiodes in a Continuous Crystal Gamma Camera
  105. Evaluation of a Large Pixellated Cadmium Zinc Telluride Detector for Small Animal Radionuclide Imaging
  106. A high efficiency small animal imaging system based on position sensitive avalanche photodiodes
  107. Resolution enhancement in dual-energy x-ray imaging
  108. Evaluation of a full-scale gas microstrip detector for low-dose X-ray imaging
  109. Physical characteristics of a low-dose gas microstrip detector for orthopedic x-ray imaging
  110. Pincushion Distortion Correction in Position Sensitive Avalanche Photodiodes
  111. Investigation of a Continuous Crystal PSAPD-Based Gamma Camera
  112. High Resolution Position Sensitive Avalanche Photo Diode Gamma Ray Imaging